Auto-login JWT tools for firmware 2.2.0.
Full walkthrough (ports, auth, fan kicks, safety):
../CONNECT_AND_FANS.md
These scripts are not BIP-110-specific — they only talk to the miner over LAN HTTP.
Keep them in this repo (or a local working copy such as O:\HSlite); your BIP-110 / DATUM tree can stay separate.
cd sc-lite/python
pip install -r requirements.txt # or: pip install pycryptodome
export SCLITE_IP='192.168.x.x'
export SCLITE_PASSWORD='your-miner-password' # often factory 123456789 — change itWindows PowerShell:
cd sc-lite\python
pip install -r requirements.txt
$env:SCLITE_IP='192.168.0.202'
$env:SCLITE_PASSWORD='your-miner-password'
# password can also go in sclite_temp_manager.json -> miner.passwordpython sclite_snapshot.pyYou should see the powerplan, per-board temps, fans, and hashrate.
If login fails, fix SCLITE_IP / password before anything else.
python sclite_set_fan.py 70
python sclite_snapshot.pyFans should jump within a few seconds (e.g. ~1000 → ~1700 RPM).
Optional restore to stock auto:
python sclite_restore_auto.pycopy sclite_temp_manager.example.json sclite_temp_manager.json
python sclite_temp_manager.py --config sclite_temp_manager.json| Mode | Role | tempcontrol |
|---|---|---|
single |
Basic — temp ≥ on_temp → kick to kick_fan |
Keep ON (safer) |
steps |
Advanced but safer — ladder e.g. ≥60→55, ≥65→60, ≥70→65. Re-pulses every cooldown_s while still in that zone (needed because tc ON fades the kick). Drops to a lower step only when temp falls below that step’s threshold. |
Keep ON |
smooth |
Continuous ramp (weighted history). Fiddle min_temp/max_temp/min_fan/max_fan. Not fully tested yet (experimental). |
Prefer OFF so stock fanctrl doesn’t fight you; use abort + restore_auto_on_exit |
python sclite_temp_manager.py --config sclite_temp_manager.steps.example.json
python sclite_temp_manager.py --config sclite_temp_manager.smooth.example.json
python sclite_temp_manager.py --config sclite_temp_manager.json --mode smoothInteractive keys: m cycle mode · [ ] on_temp · { } kick_fan · p pause · k force · r restore · s save · q quit
- Keep
tempcontrolon (default) - Abort 90°C by default
- Don’t leave
tempcontroloff tests unattended
python sclite_snapshot.py
python sclite_set_fan.py 70
python sclite_restore_auto.py
python sclite_watch.py
python sclite_temp_manager.py --config sclite_temp_manager.json
python sclite_temp_manager.py --config sclite_temp_manager.steps.example.json
python sclite_temp_manager.py --config sclite_temp_manager.smooth.example.json
# DANGEROUS: tempcontrol OFF + fan kick with auto-abort restore