Computed controls previously could fail silently while analysis returned 0. Enforce each control's calculation invariant with a named exception, catch failures at the gate, and exit 1 without an estimate report. Preserve frozen1e-9 duplicate and1e-12 calculator tolerances, all RNG streams, formulas and values.

Validation: baseline9tests/6failures → repaired9passes. Planted +1e-6 duplicate fault now produces named JSON and gate exit1/report_count0; fault removed passes. The optimized-Python regression also confirms gate exit1, and instrument P1–P12 exits0. Raw evidence experiments/e2/verification/E5/.

Depends on SITE E3 #36 and CONTRACT E1 Cubits11/cc-framework#65. No new inferential thresholds, sample rules or public claims.