69 changes: 39 additions & 30 deletions CHANGELOG.md
Original file line number Diff line number Diff line change
Expand Up @@ -6,48 +6,57 @@ All notable changes to this project will be documented in this file.

### Added

- **A meter the panel reports without a breaker space** gets power, energy and current sensors, no switch, and its own place outside the breaker grid.
- **Circuits that share a meter or relay name each other**, the panel view draws them as one slot, and current monitoring uses their combined rating.
- **An EV charger lock** where the panel lets the charger be locked, and **busbar current, line frequency and upstream protection rating** sensors where the
panel publishes them.
- **A battery the panel declares gets its device before its first reading**, reading unknown until then, and a battery fed by a circuit reports its connection.
- **Registration says when to retry** if the panel limits attempts, and setup asks only for the passphrase where the panel does not support proximity.
- **Diagnostics include the panel's device tree**, with identifiers and site details masked, so a report needs no separate capture.
- **Remote current transformer (CT) support**: a remote CT the panel reads gets power, energy and current sensors and its own place outside the breaker grid,
with no switch and no current monitoring, since it has no breaker.
- **Support for circuits that share a meter or relay**: each keeps its own entities and names the circuits it shares with in its attributes. The panel view
draws the group as one slot, and current monitoring judges it once against the members' combined rating, with an override on any member applying to the group.
- **Support for an EV charger lock** where the panel lets the charger be locked, and for **busbar current, line frequency and upstream protection rating**
sensors where the panel publishes them. On a panel with no main breaker, current monitoring judges the mains against the upstream protection rating.
- **On panels other than MAIN 32, a circuit with a solar role reads its power** and Net Energy as generation and displays as generation, and solar fed through
one gets a Solar device even where the panel publishes no inverter. A panel with no solar circuit or inverter gets no Solar device.
- **On panels other than MAIN 32, the panel view draws the breaker positions the panel reports.**
- **A battery the panel declares gets its device and entities as soon as the panel declares it**, reading unknown until its first values arrive. 2.1.x created
them only once its state of charge arrived, reloading the integration to do so.
- **Support for a battery wired to a breaker in the panel**: its BESS Connected sensor shows whether the panel can communicate with it, as it already did for a
battery connected ahead of the panel.
- **Registration honors the panel's retry limits**, saying how long to wait instead of showing an unknown error, and setup asks only for the passphrase on
panels that register by passphrase only.
- **Improved diagnostics that include the panel's device tree**, every device and property it publishes, with serial numbers, device ids and site details
masked, so reporting a problem no longer needs a separate MQTT capture.

### Changed

- **Circuits with a solar role read and display as generation**, and solar fed through such a circuit gets a Solar device without a separate inverter device.
- **A panel that publishes no solar source no longer gets a Solar device or PV Power sensor**; on an upgraded install those entities stay unavailable until
removed.
- **New installs no longer create the Status Postal Code and Status Time Zone sensors, which say where the panel is installed**; existing ones stay and keep
updating, and diagnostics redact both values.
- **The panel view draws only the breaker positions the panel has**, and shows a battery charge the panel has not reported as unknown rather than 0%.
- **Setup stops with a repair issue when the panel reports a hardware version this release has not been validated with.**
- **New installs let only administrators operate the panel**, and an existing install keeps the Who may operate the panel setting it had.
- **Setup stops with a repair issue on a panel whose hardware version this release has not been validated with**; a MAIN 32 always proceeds.
- **The Who may operate the panel option now defaults to Administrators only on new installs**, where it defaulted to Any Home Assistant user; an existing
install keeps the setting it had.

### Removed

- **The Unmapped Circuit Sensors option is removed**, because the panel publishes nothing for an empty breaker position, and the hidden Unmapped Tab sensors it
created are deleted.
- **The Unmapped Circuit Sensors option is removed, and the hidden Unmapped Tab sensors it created are deleted.** The panel publishes nothing for an empty
breaker position, so those sensors always read 0 W and 0 Wh.

### Fixed

- **An energy counter reading beyond what its breaker could ever carry is never used as the dip-compensation baseline**, so it cannot skew energy totals.
- **The current-monitoring summary is hidden while monitoring is off**, instead of reading "0 circuits".
- **A circuit or main breaker whose current monitoring is turned off no longer shows a frozen utilization or alert window** in the panel view or Get
monitoring status, and turning monitoring back on starts a fresh window rather than alerting on one opened before.
- **DSM State, DSM Grid State and Current Run Config stay on-grid on a panel with no Microgrid Interconnect Device**, instead of dropping to unknown for a
moment whenever Grid Power read near zero.
- **Power sensors show unknown while the panel is offline, and Battery, PV, Grid and Site Power show unknown whenever the panel has not published them**,
instead of a false 0 W that history and statistics could not tell from a real reading.
- **Get monitoring status reports no current or utilization for a circuit or main breaker that has not been measured yet**, instead of 0 A and 0%.
- **Favorites, current-monitoring overrides and the dashboard find circuits whatever their ids look like.**
- **With more than one panel, a current-monitoring threshold set through an entity applies to that entity's panel**, and a call naming a different panel is
refused.
- **With Auto-Compensate Energy Dips on, an energy counter reading more than its breaker could ever have carried is never taken as the baseline**, so a later
correction by the panel is no longer booked as a permanent offset that inflates that circuit's energy totals.
- **The panel view hides its current-monitoring summary while monitoring is off**, where it read "Monitoring · 0 circuits · 0 mains".
- **A circuit or main breaker with current monitoring turned off no longer shows the utilization and open alert window it had when monitoring stopped.**
- **DSM State, DSM Grid State and Current Run Config stay on-grid on a panel with no Microgrid Interconnect Device**, where they dropped to unknown for one
update whenever Grid Power read within 1 W of zero, and an automation saw each return as the grid coming back
([span-panel-api#215](https://github.com/SpanPanel/span-panel-api/issues/215)).
- **Power sensors show unknown while the panel is offline, and Battery, PV, Grid and Site Power show unknown until the panel publishes them**, where they read 0
W, which history and statistics could not tell from a real reading. The panel view shows any power, current or battery reading the panel has not reported as
"--" and leaves it out of totals. An automation or template that relied on 0 needs to handle unknown.
- **The Get monitoring status action reports no current or utilization for a circuit or main breaker that has not been measured yet**, where it reported 0 A and
0%.
- **Resolved an issue where, with more than one panel, a current-monitoring threshold set through an entity could apply to the wrong panel.**
- **Diagnostics redact the Wi-Fi network name.**
- **Each update from a panel on firmware r202633 or later costs Home Assistant's event loop the same small amount however many circuits and devices it
has**, instead of growing with each one ([span-panel-api#223](https://github.com/SpanPanel/span-panel-api/issues/223)).
- **The EV charger charge-limit number offers only the range the charger accepts**, where it offered values the charger refuses.
- **Resolved a performance issue where the integration used more of Home Assistant's processing time the more circuits and devices the panel had**, which on
low-powered hardware used excessive CPU ([span-panel-api#223](https://github.com/SpanPanel/span-panel-api/issues/223)).
- **Resolved an issue where the EV charger charge-limit number offered values below the charger's minimum**, which the charger refuses; it now offers only the
range the charger declares.

## [2.1.2] - 10/2026

Expand Down
Loading