PID Controller Design & Simulink Verification

This repository demonstrates the design, simulation, and analysis of Proportional (P), Proportional-Integral (PI), and Proportional-Integral-Derivative (PID) controllers for a third-order continuous-time system.

The project combines an automated MATLAB script for calculating parameters via the classic Ziegler-Nichols (Z-N) closed-loop tuning method with a Simulink model to verify the transient and steady-state performance.


📌 System Description

The plant model used in this project is a third-order transfer function defined as:

$$G(s) = \frac{5}{(s+2)(s+4)(s+6)} = \frac{5}{s^3 + 12s^2 + 44s + 48}$$

The MATLAB script dynamically determines the system's stability margins to extract the Ultimate Gain ($K_u$) and Ultimate Period ($P_u$) required for the tuning formulas.


🛠️ Ziegler-Nichols Tuning Parameters

The controller gains are calculated using traditional Z-N closed-loop tuning rules:

Controller Type $K_p$ $T_i$ $T_d$
Proportional (P) $0.5 \cdot K_u$ $-$ $-$
Proportional-Integral (PI) $0.45 \cdot K_u$ $P_u / 1.2$ $-$
Proportional-Derivative-Integral (PID) $0.6 \cdot K_u$ $P_u / 2$ $P_u / 8$

🚀 How to Run the Project

Prerequisites

  • MATLAB & Simulink
  • Control System Toolbox

Execution Steps

  1. Clone this repository and ensure all files are in the same working directory.
  2. Run the MATLAB script by typing PIDcontroller in the Command Window, or press Run (F5). This calculates the controller variables ($K_p, K_i, K_d$) and loads them into your workspace.
  3. Open the Simulink model file: simulinkmodel.slx.
  4. Run the Simulink simulation to feed the workspace parameters into the parallel PID blocks.
  5. Double-click the Scope block in Simulink to view the live behavioral graph.

📊 Performance & Outputs

1. Command Window Metrics

The script outputs the critical frequency-domain metrics derived from the plant's uncompensated open-loop response:

  • Ultimate Gain ($K_u$): The gain margin threshold where the system becomes marginally stable.
  • Oscillation Frequency ($\omega_u$): The phase crossover frequency in rad/s.

2. Scope Step Response Comparison

The step response behavior of each controller configuration is visualized through the Simulink Scope block:

Simulink Scope Step Response

  • Proportional Only (P): Fast response but suffers from a significant steady-state offset.
  • Proportional-Integral (PI): Eliminates the steady-state error entirely, but introduces heavy oscillations and high overshoot.
  • Proportional-Integral-Derivative (PID): Provides the optimal balance—eliminating steady-state error, dampening the system to reduce overshoot, and drastically improving settling time.

📁 Repository Structure

  • PIDcontroller.m - Main MATLAB script containing the plant definition, Z-N tuning mathematical formulas, closed-loop feedback loops, and plotting routines.
  • simulinkmodel.slx - Simulink block diagram layout containing the step input, parallel PID controller configurations, plant transfer function, and routing to the multi-input Scope.
  • Scope.png - Exported screenshot from the Simulink Scope block illustrating the performance comparison of the P, PI, and PID controllers.
  • README.md - Documentation of the project.