Warning

This is an unofficial Generac MobileLink integration. Generac systems may change at anytime, which would break the functionality of this integration, and it should not be used for anything mission critical. If you would like an alternative for whole-home generators that allows you to drop the need to maintain a MobileLink subscription, please see the ongoing discussions here for local hardware solutions using GenMon and Raspberry Pi's. Shoutout to Jeff Terrace for his blog post documenting how to set this up, so others can benefit from his experience!

As of July 26, 2026, this integration currently supports logging in with your MyGenerac/MobileLink username and password to expose your devices to Home Assistant for monitoring and automation.

Generac MobileLink/MyGenerac Home Assistant Integration

hacs

Custom Generac integration component with support for generators and propane tank monitors. It will set up the following platforms.

Platform Entities created for each generator (by entity_key)
binary_sensor is_connected, is_connecting, has_maintenance_alert, show_warning, missed_exercise, plus conditional enrolled_in_vpp, active_vpp_event, subscription_dunning
button reset_service_timer, boost_polling
sensor status, run_time, protection_time, activation_date, last_seen, connection_time, battery_voltage, device_type, dealer_email, dealer_name, dealer_phone, address, status_text, status_label, error_code, serial_number, model_number, device_ssid, panel_id, signal_strength, hours_until_service, plus conditional exercise_minutes, outdoor_temperature, device_battery_level
weather conditional weather
image conditional hero_image
Platform Entities created for each propane tank monitor (by entity_key)
binary_sensor is_connected, is_connecting, has_maintenance_alert, show_warning, plus conditional subscription_dunning
sensor status, capacity, fuel_level, remaining_fuel, estimated_runtime, fuel_type, orientation, last_reading, battery_level, address, device_type, plus conditional signal_strength, device_battery_level, outdoor_temperature
weather conditional weather
image conditional hero_image

Note: The tables above list each entity's stable entity_key (unique ID suffix). On fresh installs, Home Assistant generates entity IDs from friendly display names (for example, Outage Boost Poll for boost_polling and Reset Maintenance Timer for reset_service_timer), while existing installs preserve their entity IDs across upgrades.

example

Installation (with HACS)

NOTE: If you've previously installed this integration, delete it first from Settings -> Integrations and delete the "Custom Repository" entry in HACS (found in HACS -> Integrations -> 3 dot menu on the top right)

Click this button to skip steps 1 and 2 below: Open your Home Assistant instance and open a repository inside the Home Assistant Community Store.

  1. On the HACS -> Integrations page, click the Explore & Download Repositories button
  2. Search the list for generac and select it to open the details page
  3. On the bottom right, click the Download button
  4. Restart Home Assistant (not the quick reload option)
  5. Once Home Assistant comes back online, go to Settings -> Integrations
  6. Click the Add Integration button
  7. Search the list for generac and select it
  8. Enter your MyGenerac email and password (the same credentials you use in the MobileLink mobile app).
  9. If your account has two-factor authentication, a second screen asks for the verification code sent by text (SMS), your authenticator app, or email. Enter the most recent code and submit. (Push-prompt or security-key 2FA can't be completed here — approve the login in the MobileLink app, or switch your Generac/ecobee account to code-based 2FA, then retry.)
  10. The integration should initialize and begin pulling your device information within seconds

Installation (without HACS)

  1. Using the tool of choice open the directory (folder) for your HA configuration (where you find configuration.yaml).
  2. If you do not have a custom_components directory (folder) there, you need to create it.
  3. In the custom_components directory (folder) create a new folder called generac.
  4. Download all the files from the custom_components/generac/ directory (folder) in this repository.
  5. Place the files you downloaded in the new directory (folder) you created.
  6. Restart Home Assistant
  7. In the HA UI go to "Configuration" -> "Integrations" click "+" and search for "generac"
  8. Enter your MyGenerac email and password (the same credentials you use in the MobileLink mobile app).
  9. If your account has two-factor authentication, a second screen asks for the verification code sent by text (SMS), your authenticator app, or email. Enter the most recent code and submit. (Push-prompt or security-key 2FA can't be completed here — approve the login in the MobileLink app, or switch your Generac/ecobee account to code-based 2FA, then retry.)
  10. The integration should initialize and begin pulling your device information within seconds

Configuration is done in the UI

Options (Configure)

Open Settings → Devices & services → Generac MobileLink → Configure to adjust enabled platforms, polling intervals, readiness thresholds, and fuel autonomy calculation:

  • Estimated fuel burn rate (gal/h) (fuel_burn_rate, default 2.2 gal/h LP at typical 50% load): Used by the propane monitor Estimated Runtime Remaining (estimated_runtime) sensor to convert Remaining Fuel (remaining_fuel, in gallons) into hours of generator runtime remaining (remaining_fuel / fuel_burn_rate).

Adaptive Polling & Outage Boost

To stay gentle on Generac's rate-limited cloud API during normal standby while reacting quickly during exercises, outages, and warnings, polling adapts automatically between two configurable intervals (both clamped to at least 10 seconds):

  • Idle polling interval (scan_interval): Default 900 seconds (15 minutes). Used when all devices are idle/ready.
  • Active polling interval (active_scan_interval): Default 120 seconds (2 minutes), capped at min(scan_interval, active_scan_interval) so fast polling never slows down a shorter idle interval.

Fast polling activates automatically whenever any generator is Running, Exercising, or Warning, or when any device reports isConnecting, showWarning, or isRunning. After the fleet returns to idle, fast polling remains active for a 300-second (5-minute) cooldown before returning to the idle interval.

You can also trigger fast polling manually (for example, from an automation triggered by a utility power-loss sensor) using either:

  • Outage Boost Poll button (boost_polling, default entity ID button.<device>_outage_boost_poll): Created for each generator; pressing it immediately refreshes data and enables boost polling for 30 minutes.
  • generac.boost_polling action (service): Switches loaded entries into boost polling and triggers an immediate refresh. Accepts optional duration_minutes (1–120, default 30) and optional entry_id (targets all loaded Generac entries if omitted).

Telemetry, Long-Term Statistics & Diagnostics

  • Long-Term Statistics (LTS): Operational numeric sensors expose Home Assistant state_class (total_increasing on run_time and protection_time; measurement on battery_voltage, exercise_minutes, outdoor_temperature, capacity, fuel_level, remaining_fuel, estimated_runtime, signal_strength, device_battery_level, and hours_until_service) for history graphs and long-term recorder statistics.
  • Fault, VPP & Subscription Telemetry: Generators expose active fault codes via Error Code (error_code), and—when present in the MobileLink payload—Virtual Power Plant status (enrolled_in_vpp, active_vpp_event) and subscription billing alerts (subscription_dunning).
  • Diagnostic Categorization: Static metadata and diagnostic entities (serial/model/panel ID, device SSID/type, address, dealer contact info, activation/last-seen/connection timestamps, fuel type, tank orientation, signal strength, VPP enrollment, and subscription billing alert) are grouped under Home Assistant's Diagnostic entity category to keep primary dashboards uncluttered.

Readiness Tracking, Maintenance Timer & Repairs Alerts

Each generator automatically tracks exercise activity and maintenance runtime baselines using Home Assistant storage (persisting cleanly across restarts without reloading the integration):

  • Maintenance Service Timer:
    • Hours Until Service (hours_until_service, default entity ID sensor.<generator>_hours_until_service) shows estimated runtime hours remaining until the configured service interval (default 100 hours, configurable via Options -> service_interval_hours; set to 0 to disable).
    • On first setup, the baseline initializes to the generator's current run_time to avoid false day-1 alarms.
    • After completing maintenance (oil change, filter, etc.), press Reset Maintenance Timer (reset_service_timer, default entity ID button.<generator>_reset_maintenance_timer) on the device page to reset the baseline to the current run hours and clear any timer-based Repairs issue immediately.
  • Exercise Readiness Tracking:
    • Missed Exercise (missed_exercise, default entity ID binary_sensor.<generator>_missed_exercise) turns on if no Running/Exercising status or run-hour increase is observed within exercise_interval_days (default 16 days to cover weekly and biweekly schedules; set to 0 to disable).
  • Proactive Home Assistant Repairs Alerts:
    • low_battery_voltage: raised when generator starting battery voltage drops below low_battery_threshold (default 12.2 V).
    • missed_exercise: raised when the generator exceeds exercise_interval_days without observed activity.
    • maintenance_due: raised when runtime since the last service reset reaches service_interval_hours or Mobile Link reports a maintenance alert.
    • subscription_dunning: raised when Mobile Link reports a past-due/dunning subscription status.

Bundled Automation Blueprints

When the integration sets up, three ready-to-use automation blueprints are automatically installed to <config>/blueprints/automation/generac/:

  1. Generac Outage Load Shedding (generac_outage_load_shedding.yaml) — Sheds high-draw entities when status transitions to Running (ignoring Exercising cycles), waits for Ready stabilization, and optionally restores previously active loads with a stagger delay.
  2. Generac Fault & Dealer Contact Alert (generac_fault_dealer_alert.yaml) — Sends a notification populated with generator status, diagnostic status_text, optional error_code, and your preferred dealer's name and phone number on Warning, Stopped, Communication Issue, warning, or maintenance alerts.
  3. Generac Pre-Storm Readiness Digest (generac_storm_readiness_digest.yaml) — Sends a readiness digest with status, connectivity, battery voltage, hours until service, and optional propane fuel level, remaining fuel, and estimated runtime when a weather alert or trigger entity turns on.

Username + Password Authentication

This integration previously used a cookie-fishing authentication workflow. As of PR #267, it has now been replaced by a standard OAuth workflow similar to the mobile app, using your username and password, with auto-refreshing token retrieval. You no longer need to enter your cookie's string!

Session expiry (every ~90 days)

Generac's sign-in sessions expire 90 days after you log in, no matter how often the integration uses them. You have two options:

  • Remember password (checkbox at sign-in, reauth and reconfigure): the password is stored in Home Assistant and the integration signs in again on its own when the session expires. This doesn't work for accounts that require a verification code (SMS / email / authenticator), because the code can't be entered unattended.
  • Without it: a Repairs warning appears about 10 days before expiry. Use Reconfigure on the integration to sign in again before your devices stop updating.

Important

Fair Warning

Status Quo in summer 2026: This is an unofficial Generac integration, which requires using undocumented APIs in order to access the data of your Generac devices using your username and password. This is because Generac has changed (once again) the authentication workflow to actively block third-party access. They also originally stated that Home Assistant users were overloading their API. We have since adapted to the new authentication method and switched to adaptive polling—defaulting to every 900 seconds (15 minutes) while idle and 120 seconds (2 minutes) while a generator is active—to be a "good" user of the API and minimize traffic to their servers. Both polling intervals can be tuned to your needs in the options panel of the HA integration once you have set it up, as seen here.

This approach implies that when Generac is going to change something in their non-public/undocumented API, it's quite likely that the integration will break instantly.

It's impossible to predict when this will happen, but I will try to keep the integration up-to-date and working as long as possible.

Contributions are welcome!

If you want to contribute to this please read the Contribution guidelines

Credits

This project was generated from @oncleben31's Home Assistant Custom Component Cookiecutter template.

Code template was mainly taken from @Ludeeus's integration_blueprint template

Forked from the original implementation created by @bentekkie