Skip to content

byte-vector-to-hexstring don't strip leading "x" #1758

Closed

Description

@autowp
create table users
(
  ...
  uuid binary(16) null,
)
CAST
  column users.uuid to uuid drop typemod using byte-vector-to-hexstring,

Result:

ERROR: invalid input syntax for type uuid: "xa3cda7d500a64111814659127a8d5e42"
  Where: COPY users, line 1, column uuid: "xa3cda7d500a64111814659127a8d5e42"

Activity

  1. dimitri commented on Jul 15, 2026

    @dimitri
    Owner

    PR #1761 adds two fixes for this:

    1. byte-vector-to-hexstring is fixed — it now strips the bare X prefix that MySQL binary columns produce, so the existing cast in the issue will work once the fix is in.

    2. New binary-to-uuid transform — produces the canonical hyphenated UUID format (xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx) directly, which is cleaner:

    CAST
      column users.uuid to uuid drop typemod using binary-to-uuid,

    Once the PR is merged, CI will automatically publish an updated pgloader.jar at:

    https://github.com/dimitri/pgloader/releases/download/v4-dev/pgloader.jar

    You can download and run it with:

    wget https://github.com/dimitri/pgloader/releases/download/v4-dev/pgloader.jar
    java -jar pgloader.jar your.load

    See install.rst for full installation details including the Java version requirement (17+).