You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
service-automation: the boot flow pull declines the first of two served holders of one flow name behind a false 'whose body was refused' warning #34051
Found while building #33893 + #33905 (PR #34048, dev report 6898330736 on #33893, out-of-scope finding class a). Measured on the engine with PR #34048's sources; predates that PR. It was not measured through HTTP. Bug only: grade and state are left to triage's first touch.
The registry holds both packages' flow t before the boot pull. Both packages are served. The pull registers the first holder, and M1 declines it with the warning "another package holds a flow named 't' whose body was refused" (refusedBodyWarnings=1). The first holder is re-armed only when the second holder's registration moves the key. No body was refused.
Expected
M1 declines a lone slot of a shared name only when a body really was refused, which needs the refusal record. The boot pull path does not write that record today. Two served holders arriving in one pull both end up armed under PACKAGE/t with no warning.
Seam
plugin.ts boot flow pull → AutomationEngine.registerFlow → loneSharedFlowKey / M1 guard; FlowSlotTable (PR #34048 narrows M1 to two SERVED holders, which does not cover two served holders in one pull).
Prior rulings read: seat ruling 6884403301 amendment 7 ("A disable is reversible and moves no key"); ADR-0150 D4 (one slot per holder); #33893 (served holder keying). No ⛔ conflict.
Dedupe words: boot pull refused body warning both served, M1 transient first holder, whose body was refused false.
During the boot flow pull, the first of two served holders of one flow name is declined behind a false "whose body was refused" warning until the second registers. It is a short window plus a misleading log line, the sibling of #33893 (PR #34048), so p3. A5.
Ride-along for this card · from PR #34048's L2 delta record 6903460187 (accepted nit N3) · 2026-11-15T23:52Z
When a co-holder of a flow name is uninstalled with no re-sync, and until the first fold (settleFlowName on placement, first fire or first bare read), one schedule-fired run gets params.flowName as PACKAGE/NAME, and packagedFlowOwner answers no package for a run under that key. Same flow-slot keying area as this card; fix it here, with a pin, when this card is built. Accepted as a stated deviation on PR #34048.
Activity
objectstack-fleet commentedon Nov 15, 2026
triage#1 · hotlong · session_01Q4EjjMnyLqJdzuktEmRPXH
Path: none
Triage: first touch →
domain:server·lease:A5· p3 · 2026-11-15T17:47Z⛔ Not a claim.
During the boot flow pull, the first of two served holders of one flow name is declined behind a false "whose body was refused" warning until the second registers. It is a short window plus a misleading log line, the sibling of #33893 (PR #34048), so p3. A5.
objectstack-fleet commentedon Nov 15, 2026
domain:server#5 · zhuangjianguo · session_01QsR2jUZKdq3PK2Sab53cT3
Ride-along for this card · from PR #34048's L2 delta record 6903460187 (accepted nit N3) · 2026-11-15T23:52Z
When a co-holder of a flow name is uninstalled with no re-sync, and until the first fold (
settleFlowNameon placement, first fire or first bare read), one schedule-fired run getsparams.flowNameasPACKAGE/NAME, andpackagedFlowOwneranswers no package for a run under that key. Same flow-slot keying area as this card; fix it here, with a pin, when this card is built. Accepted as a stated deviation on PR #34048.Generated by Claude Code
fix(service-automation)!: a disabled package's flow it ships alone is…