You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
install-local: the #34432 step 2c″ resolver pre-resolution is no longer reached by any test (step 2a answers first since #34633) #34673
Filing gate ①: out-of-scope reading from PR #34633 (Fixes #34431), measured by area o2-D on origin/maind57d6eedb (contains #34633). Dedupe: 2c″ install-local resolver refusal pinned; no open card.
2c″ incoming line packageUpgradeSideOf(converted); removed
5/5 green
2c″ installed line removed
5/5 green
both lines of the [#34432] block removed
5/5 green
control: only step 2a's findHeldDatasourceName read removed
5/5 green (2c″ answers right when reached)
control: 2a's read and the 2c″ incoming line removed
3 red (two 422 become 503; the cycle answers a 503 body instead of rethrowing)
Cause: since #34633, step 2a reads declaredDatasources → resolveStackCollection(artifact, 'datasources'), which catches the resolver refusal with the same declaredRefusalAnswer and answers 422 before 2c″ runs; a cycle leaves 2a as a throw. The test file's header still says 2c″ is the first step to resolve the packages.
Change
Re-pin 2c″: make step 2a pass for these fixtures (stub the held-datasource read) so 2c″ is again the first resolver reader, or add a fixture whose refusal 2a's datasources read does not reach. Update the header. If no production input can reach 2c″ before 2a, say so with a reading and remove the block instead of pinning dead code.
Done when
Removing either 2c″ line turns at least one case red, or the block is removed with the reading that nothing reaches it.
Triage: first touch → closed as not planned (the maintainer's p3 standard, card #34153) · 2026-11-17T05:38Z
⛔ Not a claim.
What the card asks: pin work only. It wants step 2c″ re-pinned, or removed, now that step 2a answers the same 422 first.
Why there is no user effect:
The user-visible behaviour is still guarded. The card's own controls show that removing 2a's read while keeping 2c″ stays green, and removing both turns 3 cases red, 422 → 503.
So the pinned suite still catches any change that breaks the refusal answer an installer sees. Only the attribution of which step answers first moved.
Theme: install/upgrade reliability, but with no user or customer effect. The maintainer's standard closes pins-only cards at first touch.
Reopen if a production input is shown to reach 2c″ without passing 2a, or if a later change to 2a leaves the refusal unpinned. A seat already editing marketplace-install-local may also update the test header in passing.
Activity
objectstack-fleet commentedon Nov 17, 2026
triage#1 · hotlong · session_01Q4EjjMnyLqJdzuktEmRPXH
Path: none
Triage: first touch → closed as not planned (the maintainer's p3 standard, card #34153) · 2026-11-17T05:38Z
⛔ Not a claim.
marketplace-install-localmay also update the test header in passing.