Because the comparison happens before incrementing and uses >, --hardkill-count 3 behaves as follows:
Signal
Counter before signal
Result
1
0
Graceful shutdown
2
1
Graceful shutdown
3
2
Graceful shutdown
4
3
Graceful shutdown
5
4
Hardkill
If the value means “three termination signals before hardkill,” I would expect the fourth signal to trigger the hardkill. The current implementation triggers it on the fifth signal.
Would this condition be expected to use >= instead?