30 changes: 21 additions & 9 deletions README.md
Original file line number Diff line number Diff line change
Expand Up @@ -9,16 +9,16 @@

**Custom Generac integration component with support for generators and propane tank monitors. It will set up the following platforms.**

| Platform | Entities created for each generator |
| --------------- | -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| `binary_sensor` | `is_connected`, `is_connecting`, `has_maintenance_alert`, `has_warning`, `missed_exercise` |
| `button` | `reset_service_timer`, `boost_polling` |
| `sensor` | `status`, `run_time`, `protection_time`, `activation_date`, `last_seen`, `connection_time`, `battery_voltage`, `device_type`, `dealer_email`, `dealer_name`, `dealer_phone`, `address`, `status_text`, `status_label`, `serial_number`, `model_number`, `device_ssid`, `panel_id`, `hours_until_service` |
| Platform | Entities created for each generator |
| --------------- | --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| `binary_sensor` | `is_connected`, `is_connecting`, `has_maintenance_alert`, `has_warning`, `missed_exercise`, plus conditional `enrolled_in_vpp`, `active_vpp_event`, `subscription_dunning` |
| `button` | `reset_service_timer`, `boost_polling` |
| `sensor` | `status`, `run_time`, `protection_time`, `activation_date`, `last_seen`, `connection_time`, `battery_voltage`, `device_type`, `dealer_email`, `dealer_name`, `dealer_phone`, `address`, `status_text`, `status_label`, `error_code`, `serial_number`, `model_number`, `device_ssid`, `panel_id`, `signal_strength`, `hours_until_service`, optional `exercise_minutes`, `outdoor_temperature`, `device_battery_level` |

| Platform | Entities created for each propane tank monitor |
| --------------- | ------------------------------------------------------------------------------------------------------------------------------ |
| `binary_sensor` | `is_connected`, `is_connecting`, `has_maintenance_alert`, `has_warning` |
| `sensor` | `status`, `capacity`, `fuel_level`, `fuel_type`, `orientation`, `last_reading_date`, `battery_level`, `address`, `device_type` |
| Platform | Entities created for each propane tank monitor |
| --------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
| `binary_sensor` | `is_connected`, `is_connecting`, `has_maintenance_alert`, `has_warning`, plus conditional `subscription_dunning` |
| `sensor` | `status`, `capacity`, `fuel_level`, `remaining_fuel`, `estimated_runtime`, `fuel_type`, `orientation`, `last_reading_date`, `battery_level`, `address`, `device_type`, optional `signal_strength`, `device_battery_level`, `outdoor_temperature` |

![example][exampleimg]

Expand Down Expand Up @@ -66,6 +66,12 @@ Click this button to skip steps 1 and 2 below: [![Open your Home Assistant insta

## Configuration is done in the UI

### Options (`Configure`)

Open **Settings → Devices & services → Generac MobileLink → Configure** to adjust enabled platforms, polling intervals, readiness thresholds, and fuel autonomy calculation:

- **Estimated fuel burn rate (gal/h)** (`fuel_burn_rate`, default `2.2` gal/h LP at typical 50% load): Used by the propane monitor `Estimated Runtime Remaining` (`estimated_runtime`) sensor to convert `Remaining Fuel` (`remaining_fuel`, in gallons) into hours of generator runtime remaining (`remaining_fuel / fuel_burn_rate`).

### Adaptive Polling & Outage Boost

To stay gentle on Generac's rate-limited cloud API during normal standby while reacting quickly during exercises, outages, and warnings, polling adapts automatically between two configurable intervals (both clamped to at least `10` seconds):
Expand All @@ -80,6 +86,12 @@ You can also trigger fast polling manually (for example, from an automation trig
- **Outage Boost Poll button (`button.<device>_outage_boost_poll`)**: Created for each generator; pressing it immediately refreshes data and enables boost polling for `30` minutes.
- **`generac.boost_polling` action (service)**: Switches loaded entries into boost polling and triggers an immediate refresh. Accepts optional `duration_minutes` (`1`–`120`, default `30`) and optional `entry_id` (targets all loaded Generac entries if omitted).

### Telemetry, Long-Term Statistics & Diagnostics

- **Long-Term Statistics (LTS)**: Operational numeric sensors expose Home Assistant `state_class` (`total_increasing` on `run_time` and `protection_time`; `measurement` on `battery_voltage`, `exercise_minutes`, `outdoor_temperature`, `capacity`, `fuel_level`, `remaining_fuel`, `estimated_runtime`, `signal_strength`, `device_battery_level`, and `hours_until_service`) for history graphs and long-term recorder statistics.
- **Fault, VPP & Subscription Telemetry**: Generators expose active fault codes via `Error Code` (`error_code`), and—when present in the MobileLink payload—Virtual Power Plant status (`enrolled_in_vpp`, `active_vpp_event`) and subscription billing alerts (`subscription_dunning`).
- **Diagnostic Categorization**: Static metadata and diagnostic entities (serial/model/panel ID, device SSID/type, address, dealer contact info, activation/last-seen/connection timestamps, fuel type, tank orientation, signal strength, VPP enrollment, and subscription billing alert) are grouped under Home Assistant's **Diagnostic** entity category to keep primary dashboards uncluttered.

### Readiness Tracking, Maintenance Timer & Repairs Alerts

Each generator automatically tracks exercise activity and maintenance runtime baselines using Home Assistant storage (persisting cleanly across restarts without reloading the integration):
Expand Down
56 changes: 55 additions & 1 deletion custom_components/generac/binary_sensor.py
Original file line number Diff line number Diff line change
Expand Up @@ -6,6 +6,7 @@
from homeassistant.components.binary_sensor import BinarySensorDeviceClass
from homeassistant.components.binary_sensor import BinarySensorEntity
from homeassistant.config_entries import ConfigEntry
from homeassistant.const import EntityCategory
from homeassistant.core import HomeAssistant
from homeassistant.helpers.entity_platform import AddEntitiesCallback

Expand Down Expand Up @@ -38,8 +39,17 @@ def sensors(item: Item | None = None) -> list[Type[GeneracEntity]]:
GeneracMaintenanceAlertSensor,
GeneracWarningSensor,
]
if item is not None and item.apparatus.type == DEVICE_TYPE_GENERATOR:
if item is None:
return lst
if item.apparatus.type == DEVICE_TYPE_GENERATOR:
lst.append(GeneracMissedExerciseSensor)
if (
item.apparatusDetail.enrolledInVpp is not None
or item.apparatusDetail.hasActiveVppEvent is not None
):
lst.extend([GeneracVppEnrolledSensor, GeneracActiveVppEventSensor])
if item.apparatusDetail.subscription is not None:
lst.append(GeneracSubscriptionDunningSensor)
return lst


Expand Down Expand Up @@ -123,3 +133,47 @@ class GeneracMissedExerciseSensor(GeneracEntity, BinarySensorEntity):
def is_on(self) -> bool:
"""Return True if the generator has missed its exercise window."""
return bool(self.coordinator.is_missed_exercise(self.device_id))


class GeneracVppEnrolledSensor(GeneracEntity, BinarySensorEntity):
"""Whether the generator is enrolled in a Virtual Power Plant program."""

entity_key = "enrolled_in_vpp"
entity_label = "VPP Enrolled"

_attr_entity_category = EntityCategory.DIAGNOSTIC

@property
def is_on(self):
"""Return true if the generator is enrolled in VPP."""
return bool(self.aparatus_detail.enrolledInVpp)


class GeneracActiveVppEventSensor(GeneracEntity, BinarySensorEntity):
"""Whether a Virtual Power Plant dispatch event is currently active."""

entity_key = "active_vpp_event"
entity_label = "Active VPP Event"

@property
def is_on(self):
"""Return true if a VPP event is active."""
return bool(self.aparatus_detail.hasActiveVppEvent)


class GeneracSubscriptionDunningSensor(GeneracEntity, BinarySensorEntity):
"""Whether the Mobile Link subscription is in billing dunning."""

entity_key = "subscription_dunning"
entity_label = "Subscription Billing Alert"

_attr_device_class = BinarySensorDeviceClass.PROBLEM
_attr_entity_category = EntityCategory.DIAGNOSTIC

@property
def is_on(self):
"""Return true if subscription billing is in dunning."""
return bool(
self.aparatus_detail.subscription
and self.aparatus_detail.subscription.isDunning
)
21 changes: 20 additions & 1 deletion custom_components/generac/config_flow.py
Original file line number Diff line number Diff line change
Expand Up @@ -22,6 +22,7 @@
"""
import asyncio
import logging
import math
import time

import aiohttp
Expand All @@ -39,6 +40,7 @@
from .const import CONF_ACTIVE_SCAN_INTERVAL
from .const import CONF_DPOP_PEM
from .const import CONF_EXERCISE_INTERVAL_DAYS
from .const import CONF_FUEL_BURN_RATE
from .const import CONF_MFA_CODE
from .const import CONF_OPTIONS
from .const import CONF_PASSWORD
Expand All @@ -49,6 +51,7 @@
from .const import CONF_TOKEN_ISSUED_AT
from .const import CONF_USERNAME
from .const import DEFAULT_ACTIVE_SCAN_INTERVAL
from .const import DEFAULT_FUEL_BURN_RATE
from .const import DEFAULT_SCAN_INTERVAL
from .const import DOMAIN
from .utils import async_client_session
Expand Down Expand Up @@ -483,6 +486,8 @@ def async_get_options_flow(config_entry):

def _option_validator(key: str, option_type: type):
"""Build a Voluptuous validator for an integration option."""
if key == CONF_FUEL_BURN_RATE:
return vol.All(vol.Coerce(float), vol.Range(min=0.0, min_included=False))
if option_type is float:
return vol.All(vol.Coerce(float), vol.Range(min=0.0))
if key in (CONF_SERVICE_INTERVAL_HOURS, CONF_EXERCISE_INTERVAL_DAYS):
Expand All @@ -496,6 +501,20 @@ class GeneracOptionsFlowHandler(config_entries.OptionsFlow):
def __init__(self, config_entry):
self.options = dict(entry_options(config_entry))

@staticmethod
def _option_default(key: str, opt: dict, current: dict):
"""Return a safe form default for an option key."""
default = current.get(key, opt["default"])
if key == CONF_FUEL_BURN_RATE:
if isinstance(default, bool):
return DEFAULT_FUEL_BURN_RATE
try:
rate = float(default)
except (TypeError, ValueError):
return DEFAULT_FUEL_BURN_RATE
return rate if math.isfinite(rate) and rate > 0 else DEFAULT_FUEL_BURN_RATE
return default

async def async_step_init(self, user_input=None): # pylint: disable=unused-argument
return await self.async_step_user()

Expand All @@ -509,7 +528,7 @@ async def async_step_user(self, user_input=None):
data_schema=vol.Schema(
{
vol.Required(
k, default=self.options.get(k, v["default"])
k, default=self._option_default(k, v, self.options)
): _option_validator(k, v["type"])
for k, v in CONF_OPTIONS.items()
}
Expand Down
3 changes: 3 additions & 0 deletions custom_components/generac/const.py
Original file line number Diff line number Diff line change
Expand Up @@ -34,6 +34,7 @@
DEFAULT_ACTIVE_SCAN_INTERVAL = 120
ACTIVE_COOLDOWN_SECONDS = 300
DEFAULT_BOOST_DURATION_MINUTES = 30
DEFAULT_FUEL_BURN_RATE = 2.2
SERVICE_BOOST_POLLING = "boost_polling"

# Platforms
Expand Down Expand Up @@ -65,6 +66,7 @@
CONF_DPOP_PEM = "dpop_pem"
CONF_SCAN_INTERVAL = "scan_interval"
CONF_ACTIVE_SCAN_INTERVAL = "active_scan_interval"
CONF_FUEL_BURN_RATE = "fuel_burn_rate"
CONF_SERVICE_INTERVAL_HOURS = "service_interval_hours"
CONF_EXERCISE_INTERVAL_DAYS = "exercise_interval_days"
CONF_LOW_BATTERY_THRESHOLD = "low_battery_threshold"
Expand All @@ -90,6 +92,7 @@
**bool_opts,
CONF_SCAN_INTERVAL: {"type": int, "default": DEFAULT_SCAN_INTERVAL},
CONF_ACTIVE_SCAN_INTERVAL: {"type": int, "default": DEFAULT_ACTIVE_SCAN_INTERVAL},
CONF_FUEL_BURN_RATE: {"type": float, "default": DEFAULT_FUEL_BURN_RATE},
CONF_SERVICE_INTERVAL_HOURS: {
"type": int,
"default": DEFAULT_SERVICE_INTERVAL_HOURS,
Expand Down