Skip to content

Fix display freezing below -9.9 °C and at 100 % humidity, add leading zero at x.9 - #201

Open
altoing wants to merge 1 commit into
devbis:masterfrom
altoing:fix/display-edge-cases
Open

altoing wants to merge 1 commit into
devbis:masterfrom
altoing:fix/display-edge-cases

Conversation

@altoing

@altoing altoing commented Sep 29, 2026

Copy link
Copy Markdown

Three small display fixes, no behaviour change otherwise:

  • Below -9.9 °C the LCD freezes. With a decimal point the big number only fits -9.9…199.9, so show_big_number() returns early and the last value stays on screen, e.g. it shows -9.9 through a cold night. The same happens in °F. Now whole degrees are shown below that (-15), like °F already does above 99.9.
  • At 100 % humidity the LCD freezes for the same reason: show_small_number() rejects 100. The shown value is now capped at 99.
  • 0.9 is shown as .9 (and -0.9 as -.9). The leading zero was only added for number < 9; it's now < 10.

Built with the repo Dockerfile (SDK 3.7.2.0).

…g leading zero at x.9

- Below -9.9 °C (or °F) the value does not fit the big number with a
  decimal point, so show_big_number() returned early and the LCD kept
  the last value. Show whole degrees instead (e.g. -15).
- At 100 % humidity show_small_number() returned early for the same
  reason. Cap the shown value at 99.
- 0.9 was shown as ".9": the leading zero was only added below 9.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>